The Commercial Imperative for Power Quality Monitoring
![]() |
An Increasing ConcernPower quality has become a foremost concern for both industrial & commercial electrical energy consumers and power utilities, due to the increasing presence of induced harmonic voltages and currents in the electrical supplies. Harmonics, voltage sag/swells, transients, and poor power factor all contribute to an increased risk of serious damage to electrical plant and equipment and the consequent high cost of repairs, plus loss of supply and the consequent customer dissatisfaction. |
The Invisible RiskThe extent of the potential risk and actual cost of poor power quality often remains hidden from view until either monitoring equipment is installed, or a major failure event falls into the lap of the unsuspecting user. |
|
Datasheet |
|
| See PQ features for ION8650 |
The True Cost of Poor Power QualityThe true cost of poor power quality varies from site to site depending on;
In almost every instance this risk and the resulting cost is many times higher than anticipated. |
|
Preventing DowntimeSags, transients, outages, harmonics or poor power factor can cost a company tens, hundreds of thousands, or even millions of dollars – production time and data may be lost, employees are left idle, equipment is damaged. Power downtime can result in repercussions throughout an organization, including huge financial costs of damaged equipment, wasted materials, and lost productivity. An ION energy management system can provide comprehensive solutions for preventing power downtime. |
|
Continual MonitoringAs harmonic sources become more prevalent, it is important to have the analytical tools necessary by way of metering with power quality capability, to identify potential problem sources and help in determining the preventative or corrective measures necessary to improve power quality in electrical distribution systems. |
|
Sources of HarmonicsHarmonics are typically generated within a power distribution system by nonlinear loads such as;
|
![]() |
|
Harmonic currents from individual phases such as those generated by personal computers within networks, can add in the neutral line, sometimes producing dangerously high neutral currents creating fire hazards. In many instances the original electrical distribution of a building did not need to take this into account as the amount of non-linear load was a small percentage of the total load. Today with these non-linear loads being a high proportion of the load, neutral conductors are under serious threat of overheating. Neutral currents are rarely monitored even with ammeters and so this risk goes unnoticed until a fire starts or expensive equipment is damaged. |
|
Damaging EffectsPoor power quality can have serious and potentially damaging consequences, including;
|
|
Consequential EffectsHarmonics can cause not only damage to expensive power distribution equipment, but can also harm equally expensive production plant and machinery causing lost production, labour downtime and lost customers. |
|
Power FactorPower Factor is the ratio of true power (watts) to apparent power (volt-amperes) expressed in digital form between 0 1 and -0 It represents the portion of the power delivered to the load that delivers actual energy to the load. The ideal power factor value is 1.0, but usually the highest that can be achieved is around 0.95. Penalties are often imposed for power factors below 0.9. Power factor represents demand for electric current. The lower the power factor, the higher the demand for current. With some equipment such as motors or computers, current flows into the load without being usefully converted to energy. This happens if the current is distorted (has harmonics) or if the current isn’t in phase with the voltage applied. An inductive load produces lagging power factor (negative value) and a capacitive load produces leading power factor (positive value). Adverse effects of poor power factor are supply transformer overheating, and the reduction of feeder cable capacity. Both of these can be very expensive to correct. Continuous monitoring and control of power factor can improve this situation and lower operating costs. |
![]() |
Voltage and Current SequencesSequences describe the rotation and magnitude of voltage and current in a 3-phase system. In a perfectly balanced and positive-sequenced system, the rotation of voltage and current is A, B, C, A…. separated and displaced in time by 120° and equal in magnitude. Most of the time however, the phases display some measure of unbalance. Zero and negative sequences cause heating in electrical systems, and shorten motor and transformer life. ION meters analyse that unbalance. |
|
The Cost of Negative Sequence CurrentsWhen voltages applied across three-phase motor leads are unbalanced, the motor windings react by inducing large circulating currents called “negative sequence currents”. These currents cause heating. The Handbook to Assess the Insulation Condition of Large Rotating Machines by the Electric Power Research Institute (EPRI) states that: |
|
|
|
ION Metering SolutionsModern ION energy monitoring systems such as those provided by Quasar incorporate power quality monitoring functions. These can continuously monitor for PQ events and can monitor degradation trends over time, to generate email or pager alerts and inform maintenance staff of pending conditions that require attention. Depending on the types of problems found, there are a range of actions that can be undertaken to mitigate power quality problems, including but by no means limited to: |
|
|
![]() |
Quasar’s Track RecordWe have installed energy and power quality monitoring systems into many of New Zealand’s foremost industries and major network companies. Quasar is a leader in the field of providing end-to-end solutions that satisfy our customers’ energy monitoring requirements both from day one, and into the future via our Managed System Support contracts.
Trust Quasar to apply this world of experience to the benefit of your operation. |
|