Eliminate your power quality issues with active harmonic filters.
|
AccuSine PCS+ active harmonic filters provide harmonic mitigation, power factor correction and load balancing, allowing you to:
|
The issues poor power quality causes
|
Shorter equipment life
Plant and equipment are designed to operate in a system with good power quality and so power quality issues can cause overheating, damage to sensitive equipment or equipment failure. Outages and shutdowns With less equipment failure, comes less outages and shutdowns. Poor operational efficiency When power factor and harmonics issues are corrected, plant and equipment can use the full power available to them and operate more efficiently. Less outages and shutdowns also increase operational efficiency. Utility penalties Facilities with poor power factor or excess harmonics are often charged penalties by their utility, as the poor power factor and harmonics effect the network and others connected to the network. |
How active harmonic filters work
Technical data
|
Standard RMS output current ratings:
- 60 A, 120 A, 200 A, 300 A - 380 V AC to 480 V AC - 47 A, 94 A, 157 A, 235 A - 480-600 V AC - 40 A, 80 A, 133 A, 200 A - 600-690 V AC Nominal voltage: - 380-480 V AC; +10%/-15% - 480-600 V AC; +10%/-15% - 600-690 V AC; +10%/-15% - Up to 15kV with custom transformers Nominal frequency: - 50/60 Hz, ±3 Hz auto sensing Number of phases: - 3-phase, with or without neutral Spectrum cancellation: - 2nd to 51st, discrete; fully selectable per harmonic order (amplitude and on/off) Harmonic Attenuation - Closed Loop: < 3 % THD(i); max 20:1 THD(i) reduction with load harmonic current above 50 % of AccuSine PCS+ rating - Open Loop: < 5 % TDD - Requires 3 % or higher inductive impedance per nonlinear load Power factor correction: - Optimized unity PF, Leading (capacitive) or lagging (inductive) power factor (Cos φ) to target Mains current balancing - Negative sequence current injected to balance fundamental current on the mains due to load imbalance (inherently corrects displacement PF (Cos φ)) Control response time - 25 μs Harmonic correction time: - 2 cycles Reactive correction time: - 1/4 cycle Operating Temperature: - 60 A, 120 A & 200 A: IP00, IP20, UL Type Open, & UL Type 1 configurations -0 °C to 45 °C - All others 0 °C to 40 °C - Derate 2 % per degree °C to 50 °C Relative humidity: - to 95 %, noncondensing Operating Altitude: - 1000 m (derate 1 %/100 m above), max 4800 m Standards compliance/ certification: - cULus (UL508 , CSA 22.2 No. 14) - CE Certified, ABS, other local standards Display: - 144 mm QVGA TFT 64k-color touchscreen |
How's your power quality?
|
We offer a number of solutions that can provide you with information about your power quality. These include power quality audits, portable and permanent power meters, and power monitoring software.
Contact our team if you’d like more information about these solutions. |